Hyundai Venue: Controller / Heater & A/C Control Unit (DATC). Repair procedures
1. |
Self-diagnosis process.
•
|
When operating the self-diagnostics, the below fault(self-diagnostics
code) will blink at 0.5 seconds interval on the temperature
display settings(driver's side only) and the remaining
symbols are OFF .
|
|
|
2. |
Fault code display
(1) |
Continuance operation : DTC code.
|
(2) |
Continuance operation : DTC code.
|
(3) |
STEP operation.
A. Nomal or one fault code is same as a continuance operation.
B. DTC code.
|
|
3. |
If fault codes are displayed during the check, Inspect malfunction causes
by referring to fault codes.
Display
|
Fail description
|
0
|
Normal
|
11
|
Incar sensor OPEN
|
12
|
Incar sensor SHORT
|
13
|
Ambient sensor OPEN
|
14
|
Ambient sensor SHORT
|
17
|
Evaporator sensor OPEN
|
18
|
Evaporator sensor SHORT
|
19
|
Driver temp door potentionmeter OPEN or SHORT
|
20
|
Driver temp door potentionmeter Error
|
21
|
Mode door potentionmeter OPEN or SHORT
|
22
|
Mode door potentionmeter Error
|
25
|
Intake door potentionmeter OPEN or SHORT
|
26
|
Intake door potentionmeter Error
|
31
|
Auto defog sensor (OPEN)
|
Auto defog sensor (SHORT)
|
32
|
Passenger temp door potensionmeter OPEN or SHORT
|
40
|
Auto defogging actuator OPEN or SHORT
|
41
|
Defog door potentiometer Error
|
44
|
Cluster anion generator Error
|
45
|
APT CAN Signal Error
|
47
|
RPM CAN Signal Error
|
48
|
Vehicle speed CAN Signal Error
|
49
|
Engine coolant temprature CAN Signal Error
|
|
4. |
Fail safe
No
|
Item
|
Fault
|
Fail Safe
|
1
|
Incar sensor
|
Open or Short
|
Control with the value of 25°C (77.0°F)
|
2
|
Amblent sensor
|
Open or Short
|
Control with the value of 20°C (67°F)
|
3
|
Evaporator sensor
|
Open or Short
|
Control with the value of -2°C (28.4°F)
|
4
|
Mode door potentiometer
|
Open or Short
|
Fix vent position, while selecting vent mode.
Fix defrost position, while selecting all except vent mode.
Fix vent position, while selecting IG ON → OFF.
Fix defrost position, while selecting floor purge.
|
5
|
Temperature door potentiometer (MTC)
|
Open or Short
|
If temperature setting 1 - 7 step, fix at maximum cooling position.
If temperature setting 8 - 15 step, fix at maximum heating position.
|
6
|
Temperature door potentiometer (DATC)
|
Open or Short
|
If temperature setting 17°C(62.6°F) - 24.5°C(76.1°F), fix at maximum
cooling position.
If temperature setting 25°C(77°F) - 32°C(89.6°F), fix at maximum
heating position.
|
7
|
Intake door potentiometer
|
Open or Short
|
Fix vent position, while selecting vent mode.
Fix defrost position, while selecting all except vent mode.
|
|
1. |
Disconnect the negative (-) battery terminal.
|
2. |
Remove the console upper front garnish.
(Refer to Floor Console - "Floor Console Assembly")
|
3. |
Remove the center fascia panel.
(Refer to Body (Interior and Exterior) - "Center Fascia Panel")
|
4. |
Remove the audio and AVN head unit.
(Refer to Body Electrical System - "Audio Unit")
|
5. |
Loosen the mounting screws and remove the A/C & heater controller unit
(A).
|
6. |
Separate the A/C & heater controller unit connector (A) and hose (B).
|
7. |
To install, reverse the removal procedure.
•
|
Make sure the connector is connected in properly.
|
•
|
Replace any damaged clips.
|
|
|
Other information:
Inspection
1.
Turn ignition switch OFF.
2.
Disconnect IATS connector.
3.
Measure resistance between IATS terminals 3 and 4.
4.
Check that the resistance is within the specification...
In the OFF position, pull the lever gently toward you to spray washer fluid on
the windshield and to run the wipers 1-3 cycles. The spray and wiper operation will
continue until you release the lever. If the washer does not work, you may need
to add washer fluid to the washer fluid reservoir...
Categories
1. Door lock/unlock button
2. Outside rearview mirror control switch
3. Central door lock switch
4. Power window switches
5. Power window lock switch
read more